arrow_upward

CONSTRUCTION
• Frame – reinforced concrete construction• Envelope - „Hanging glass facade”
• Structural grid – 8.10 m
• Planning grid (Partitioning) – Open space
Facade
• Automatic outdoor blinds, connected to the climate station to guarantee low energy consumption and high level of comfort• Openable windows

VENTILATION AND AIR CONDITIONING
• 4-pipe air-conditioning with floor-mounted convectors• Ventilation: 40 m3/h per person in an office zone (density of 1 person per 8sq.m.)
FLOOR AND CEILING
• Clear height - 3.7 meters• Clear void - 2.9 meters
• Raised floor
• Soundproof suspended ceiling - 630 mm
• Clear floor void in the office – 250 mm
• Clear floor void in the server room – 250 mm

ELECTRICAL SUPPLY
• 2 independent power plants / power hubs• Additional power generator for safety systems and working stations
WIRING
• Floor boxes (1 box per 8 sq.m.) – with 2 data outlets and 3 power outlets on one floor• IT cables (category) – Cat 7 for wiring and Cat 6 for connectors
Illumination*
• Open plan offices: 500 Lux• Circulation zone: 300 Lux
• Toilets: 150 Lux
*The above mentioned values are in minimum (Lux)

Professional Management and maintenance
• BMS system - 24-hour monitoring (access control, alarm and security systems, air conditioning and ventilation)• Video surveillance - in and outside the building
• Security: 24-hour round the clock security guards
• Parking space
Elevators
• 12 passenger elevators• 1 freight elevator
• Access control
Mobility
• Chargers for electrical cars• Bicycle racks
• Changing rooms and bathrooms